As recommended by MCRMA, to minimise air leakage through twin skin metal roofing, the liner side of the construction must be sealed as effectively as possible.
To provide an effective seal, this will typically involve sealing at the following locations:
End Laps
Side laps and Perimeter Side Joints
Fasteners
Perimeter or butt ends in sheets
Around Penetrations, such as pipes
With a good standard of workmanship, taking care and attention to detail, a twin skin metal roof structure meeting the air tightness requirements of Approved Document L can be easily achieved.
It should be noted that the roof cladding is only one part of the envelope that contributes to air leakage. In certain situations, junctions at windows, doors, roof lights, smoke vents etc. may be more critical and hence, the attention to detail must apply to all elements of the building envelope.
Any filler or sealant is only as good as the workmanship installing the detail