SR structural roof decks provide a clean uncluttered soffit for the roofing system. 
+
 
+
It is possible to enhance this uncluttered appearance by utilising the structural roof deck as a diaphragm to transfer wind loads from the perimeter walls to internal vertical bracing/walls, therefore reducing, or removing the need for in-plane roof bracing.
+
 
+
To design the deck as a diaphragm, the following must be considered:
+
: • Implications of deck layout, void sizes/locations and vertical bracing/wall positions.
+
: • Line loads applied to the diaphragm perimeter
+
: • Fixings to all perimeter edges of roof deck area
+
: • Minimum of three vertical bracing/braced wall locations required
+
 
+
'''Note:''' It is important to note that fixing type and frequency may need to be changed to enable diaphragm design - Refer to Fig.8.13a for recommended standard fixing configurations.
+
 
+
 
+
For useful guidance on stressed skin diaphragm design, refer to:
+
 
+
'''ECCS Publication No88: European Recommendations for the Application of Metal Sheeting acting as a Diaphragm'''
+
 
+
'''BS 5950-9: Structural use of steelwork in building – Code of practice for stressed skin design'''
+
 
+
'''SBI Document 174: Stabilisation by stressed skin diaphragm action'''
+
 
+
'''BS EN 1993-1-3: Cold-formed thin gauge members and sheeting, clause 10.3'''
+
 
+
 
+
----
+
 
+
 
+
Other items within 8.0 - Design - Roof deck:-
+
: [[8.0 - Design - Roof deck]]
+
: [[8.1 - Quality]]
+
: [[8.2 - Spans]]
+
: [[8.3 - Loads]]
+
: [[8.4 - Standard end laps]]
+
: [[8.5 - Extended end laps]]
+
: [[8.6 - Raking supports and cutting]]
+
: [[8.7 - Cantilevers]]
+
: [[8.8 - Sheet lengths]]
+
: [[8.9 - Fire rating]]
+
: [[8.10 - Durability]]
+
: [[8.11 - Acoustics]]
+
: [[8.12 - Airtightness]]
+
: [[8.13 - Fixing specification]]
+
: [[8.14 - Non-fragility]]
+
: [[8.15 - Diaphragm design]]
+
: [[8.16 - Protex® warranted insulated system]]
+
: [[8.17 - Aesthetics]]
+

Latest revision as of 16:07, 14 August 2018

Section moved here

8.16 - Diaphragm design