Difference between revisions of "9.4 - Pack labels / loading-out locations"

From TGN Online
Jump to: navigation, search
 
(4 intermediate revisions by the same user not shown)
Line 1: Line 1:
Where SMD are detailing the decking layouts, decking bundles are identified on the deck GA drawings.  Packs are delivered to site with a unique identification tag (Refer to Fig 9.4a) showing a typical pack label with relevant information).   
+
Where SMD are detailing the decking layouts, decking bundles are identified on the deck GA drawings.  Packs are delivered to site with a unique identification tag (Refer to Fig 9.4a) showing a typical pack label with relevant information.   
  
Each floor deck pack has a spray stripe down one side, this indicates the orientation in which they should be loaded onto the steel frame (for aesthetic reasons roof deck packs do not come with this spray paint marking).  The spray line corresponds with the overlap side of the sheets and must face towards the setting-out point, as indicated on the relevant SMD deck GA drawing.   
+
Each floor deck pack has a coloured stripe down one side, this indicates the orientation in which they should be loaded onto the steel frame.   
 +
 
 +
The coloured stripe corresponds with the overlap side of the sheets and must face towards the setting-out point, as indicated on the relevant SMD deck GA drawing.   
  
  
Line 7: Line 9:
  
  
To provide a site control measure, the colour of the spray line on the pack indicates the decking gauge:
+
To provide a site control measure, the colour of the paint stripe on the pack indicates the deck gauge:
 +
: • Yellow = 0.7mm gauge
 +
: • White = 0.8mm gauge
 
: • Green = 0.9mm gauge  
 
: • Green = 0.9mm gauge  
 
: • Blue = 1.0mm gauge  
 
: • Blue = 1.0mm gauge  
 
: • Red = 1.2mm gauge
 
: • Red = 1.2mm gauge
 +
  
 
The loading out positions for deck packs is clearly detailed on SMD deck GA drawings.  It is essential that all packs are loaded out in the correct position and orientation to control Health and Safety issues and minimise the manual handling required.
 
The loading out positions for deck packs is clearly detailed on SMD deck GA drawings.  It is essential that all packs are loaded out in the correct position and orientation to control Health and Safety issues and minimise the manual handling required.
  
 
+
For more information, go to Section '''[[9.5 Lifting Shear Studs to Level]]'''
'''[https://smdltd.co.uk/wp-content/uploads/2016/06/SMD.DAT_.115.V4-DATA.04-Lifting-Shear-Studs-to-Level.pdf Refer to SMD Data sheet 04 for more information]'''
+
  
 
'''[https://smdltd.co.uk/wp-content/uploads/2016/07/SIG.03-Loading-out-and-Positioning.pdf For further guidance refer to industry best practice sheet SIG.03, developed in conjunction with HSE]'''
 
'''[https://smdltd.co.uk/wp-content/uploads/2016/07/SIG.03-Loading-out-and-Positioning.pdf For further guidance refer to industry best practice sheet SIG.03, developed in conjunction with HSE]'''
 +
  
  
Line 23: Line 28:
  
  
Back to '''[[Contents]]''' Page
+
Go to '''[[9.5 Lifting Shear Studs to Level|NEXT]]''' section
 
+
 
+
 
+
= '''Need Further Guidance?''' =
+
 
+
Contact us on +44 (0)1202 718 898 or email our [mailto:technical@smdltd.co.uk?Subject=Technical%20Info%20Query(online)&body=%20 Technical Team]
+

Latest revision as of 10:56, 21 April 2022

Where SMD are detailing the decking layouts, decking bundles are identified on the deck GA drawings. Packs are delivered to site with a unique identification tag (Refer to Fig 9.4a) showing a typical pack label with relevant information.

Each floor deck pack has a coloured stripe down one side, this indicates the orientation in which they should be loaded onto the steel frame.

The coloured stripe corresponds with the overlap side of the sheets and must face towards the setting-out point, as indicated on the relevant SMD deck GA drawing.


9.4a.jpg


To provide a site control measure, the colour of the paint stripe on the pack indicates the deck gauge:

• Yellow = 0.7mm gauge
• White = 0.8mm gauge
• Green = 0.9mm gauge
• Blue = 1.0mm gauge
• Red = 1.2mm gauge


The loading out positions for deck packs is clearly detailed on SMD deck GA drawings. It is essential that all packs are loaded out in the correct position and orientation to control Health and Safety issues and minimise the manual handling required.

For more information, go to Section 9.5 Lifting Shear Studs to Level

For further guidance refer to industry best practice sheet SIG.03, developed in conjunction with HSE




Go to NEXT section