In many instances, due to the low environmental impact, the preferable option is a 415 volt 3-phase (125 amp per phase, with a HRC fuse or Class D, or above, circuit breaker) mains supply.


Refer to SMD Data sheet 05


For large city centre contracts where mains supply is unavailable and access is restricted for a mobile rig, static generators approximately 3.0m long, 2.0m wide and 2.0m high weighing 6 tonnes can be provided as an alternative. Where a static generator is required, it should be positioned in a well ventilated area and consideration should be given by the Structural Engineer to its location to avoid overloading of the steel frame.