6.2 - Design rules for minimum degree of connection

From TGN Online
Revision as of 10:42, 25 January 2017 by Admin (Talk | contribs)

Jump to: navigation, search

Back to main Contents page


Composite beams with metal decking should be designed in accordance with BS EN 1994-1-1 or BS5950-3 Section 3.1:1990 +A1 2010. However, recent industry research undertaken by SCI and BCSA has resulted in non-contradictory complementary information that provides the designer with advanced rules for design of composite beams removing the conservatism that exists with the current ‘catch all’ rules contained in both BS EN 1994-1-1 and BS5950-3 Section 3.1:1990 +A1 2010.


The SCI/BCSA research provides the designer with advanced rules that cover wider design criteria than that currently available in the relevant design standards, including:

• Unpropped construction
• Partially utilised beams
• Beams with large web openings


Refer to SCI Publication P405: Minimum degree of shear connection rules for UK construction to Eurocode 4




Other items within 6.0 - Design - Floor deck Composite beam design:-

6.0 - Design - Floor deck composite beam design
6.1 - Shear stud LAW (length after weld)
6.2 - Design rules for minimum degree of connection
6.3 - Shear stud reduction factors
6.4 - BS EN 1994-1-1 Reduction factors for SMD Products
6.5 - BS5950-3 Section 3.1 Reduction factors for SMD Products
6.6 - Shear stud spacing
6.7 -Transverse reinforcement for composite beams
6.8 - Alternative Shear Connectors