11.10 VoidSafe® Protection System

From TGN Online
Jump to: navigation, search

VoidSafe® Protection System is a product that has been developed by SMD for use with metal decking and edge trim.

VoidSafe® is a moulded non-slip composite Glass Reinforced Plastic (GRP) floor grating system, it is designed, supplied and installed by SMD along with the metal deck operations.

The installation of VoidSafe® eliminates the requirement for void handrail protection systems and temporary void protection during construction, providing a final void riser protection product which minimises floor obstructions during the process.


Material specification

Two main components produce composite GRP: Polyester, resin and glass fibres. Isopthalic polyester resin is used to manufacture VoidSafe® mesh due to its flexibility and cost.


Fire resistance

• Standard Iso Resin - BS 476 Part 7 Class 2

11.10a.png

11.10b.png


Typical edge detail

The minimum bearing required for VoidSafe ® is 50mm. Around the void perimeter, the VoidSafe® is supported on specially engineered trim manufactured from 2.0mm gauge material with a 40mm recess to provide the VoidSafe® at the same level as the adjacent slab.

11.10c.png

Slab edge dimensions should be read in the same way as normal slab edge dimensions on drawings. VoidSafe® trim is marked on drawings with a ‘V’ prefix as shown below.

11.10d.png

VoidSafe® edge trim corners should be formed in such a way as to offer sufficient support for the VoidSafe® and also ensure the VoidSafe® is not cast in to the concrete slab when poured.


Edge Trim design and limitations

The acceptable overhang for VoidSafe® (VS) trim differs from that of standard edge trim. This is due to the additional load applied by the VS panel and any construction load applied to it, in addition to the wet concrete. Therefore, the acceptable overhang is governed not only by the slab depth, but also the span of the VS panel.


11.10db.png

Where VS trim is specified, the following graph must be referenced for the maximum acceptable overhang (x):

11.10dc V2.png

The above graph is based on the following assumptions as standard practice for VS trim:

• A maximum of 1.0kN/m² (100kg) is applied to the VS panel during construction – in accordance with BS EN 1991-1-6 table 4.1.

• 2.0mm gauge edge trim

• Maximum 250mm slab depth

• Standard fixings to the trim @ max. 250mm centres or enhanced Hilti X-ENP @ max. 500mm centres

In locations where the overhang exceeds that shown in the table contact SMD Technical Team for further guidance.


VoidSafe® trim supported on cantilevered deck

Where it is necessary to cantilever the deck to achieve a large edge dimension (shown in section below) and still support the VoidSafe® panels, this is only achievable along the short edge of the void (shown ticked in Fig.11.10.dd) as the fixing between deck and trim becomes the critical aspect during construction stage (pre-concreting). The long edge of the void should always have the trim fixed directly to the edge beam (in accordance with the rules outlined above) as this is the primary support for the VoidSafe® panel covering the void during the construction stage.

If cantilevering the deck is unavoidable along the long edge of the void then temporary propping will be required to the deck to provide appropriate support to the edge trim, or walking on the VoidSafe® must be prohibited until the concrete has been cast.

11.10dd.png

11.10de V2.png


Design considerations for the installation of shear studs with VoidSafe®

When designing voids and composite beams with the intention to use VoidSafe®, ensure consideration is given to the installation of shear studs on perimeter void beams as the studs can clash with the trim, depending on the size of the beams being used. Refer to Section 6.6 - Shear stud spacings for more information.


Pre-cut to size

VoidSafe® is delivered to site pre-cut to fit the void. There may be a requirement for some site cutting down, or notching required during the installation process, however this should be minimal. Should the mesh require trimming or cut on site, the correct PPE must be used. Face fitted mask with minimum P3 particle filter.

The pre-cut VoidSafe® GRP sheets are individually labelled to correspond to the SMD drawing, giving the level and phase location for each sheet.

11.10e.png


Materials off loaded on site

As with all other SMD materials, vertical distribution should be carried out by others, with horizontal distribution by SMD. The weight table located in the VoidSafe® RAMS should be consulted prior to lifting the grating sheets.


Installation on site

Thought must be given to others working around you. While VoidSafe® produces an amount of dust if cut on site, the dust created is non-toxic. Consult the COSHH data sheet prior to commencement of cutting VoidSafe®.

VoidSafe® system should be installed while the safety nets are in place below the voids being protected. There will generally be no need for handrail, or edge protection panels, where VoidSafe® grating is to be installed. However, in instances where handrails are in place, it should be removed to allow clear access for VoidSafe® grating installation.

Once each VoidSafe® grating sheet has been securely fixed in to position, the safety nets can then be de-rigged in preparation for stud welding works to follow.


Forming VoidSafe® trim

Each side of the void will need to be formed separately, with attention for overlapping of trim sections to form a neat "shelf" for the GRP mesh to be seated on.

11.10f.png


Fixing VoidSafe® trim

Edge trim must be fixed in the usual way using suitable fixings, with restraint strap installed at the centres detailed on the drawing.

11.10g.png


Bearing requirements for VoidSafe® GRP panels.

There must be a minimum bearing point of 50mm on the shortest span of the VoidSafe®.

11.10h.png


X = 114mm minimum dimension to the centre of the shear stud. This will need increasing for shallow slab depths (<150mm).

11.10i.png


The VoidSafe® grating should then be placed in to position and fixed using the washer and Tek screws supplied. There should be a minimum of 4 washers & screws per sheet, one in each corner, fixed at maximum of 1000mm centres.


11.10j.png


Fixings - Washers

Panel washers must be in each corner, be at a minimum of 1000mm centres and there should be a minimum of 4 fixings in each sheet.


Fixings - Clips

Panels can be joined using C clips with M clips used to secure panels between panel holes.


11.10k.png


When fixing VoidSafe®, it is essential that the fixing specification is followed.

Please see the below table showing fixing to use with each panel type that SMD supply. Refer to SMD’s Best Practice Data Sheet on VoidSafe® Installation for more information.


11.10l.png


Service hole forming

Only holes that have been identified, designed and approved on SMD drawings can be cut out on site by SMD. It is the responsibility of others to check the support requirements and structural properties of the VoidSafe® grating sheet in the event of further holes and cut-outs being required.

Where service penetrations are required in the VoidSafe® GRP mesh, additional trimming support may be required. Should holes be required, a detailed hole layout must be submitted to enable any additional support requirements to be specified.

This information should be made available at design stage, to avoid the need for support to be installed retrospectively.

11.10m.png


Rules for forming service holes in VoidSafe® GRP panels

• When positioning voids in a line, chose positions that do not cut across the short span of the VoidSafe® panels (refer Fig.11.10o).

• The minimum amount of grating left between holes is 300mm (7 bars of VS38).

• The minimum amount of grating between a void and an unsupported edge must be 300mm (7 bars of VS38 - refer Fig.11.10o).

• The maximum void size without possible requirement for support is 200mm (5 bars of VS38 - refer Fig.11.10n).


11.10n.png

11.10o.png


Where it is necessary to go outside of these rules, additional support is likely to be required.

Criteria that affects hole position: VoidSafe® panel load limits are typically governed by deflection so these differ depending on the application and deflection limit applied (span/200 or span/130 are often used). The above rules do not consider deflection limits.

Loading As with all typical designs, there are two types of loading to consider: The ‘rules of thumb’ are based on 0.75kN/m² UDL or point load of 1.5kN – for maintenance access from BS EN 1991-1-1.

11.10p V2.jpg


Voids that fall outside of the above rules

The VoidBEAM™ product is available for use with VoidSafe® Protection System. VoidBEAM™ provides increased strength using 110mm x 80mm steel trimmer supports placed on top of VoidSafe™ panels before holes are cut in the GRP or where excessive loadings are required on the GRP panel.

Using steel claws bolted to the VoidBEAM™ steel frame, the GRP panel is supported from above providing increased strength up to 2.5kN UDL and 1.5kN concentrated loads. See VoidBEAM™ Product page on SMD website for full product specification.

11.10q.png