Body - First line  
+
Deck sheets are designed to butt join with the ribs of the profile lined through to avoid gaps and minimise grout loss. 
  
Body - Last line
+
Metal deck is not intended to provide a watertight solution, therefore small quantities of grout and water loss are inevitable.  Gaps in excess of 5mm should be sealed using either tape or expanding foam.  Generally, gaps less than 5mm are acceptable with no special provision as they are too small to allow aggregate to escape, although grout loss will occur. 
 +
 
 +
If the soffit and trim is intended to be fully exposed in its final condition, consideration should be give at tender stage to the taping of all joints prior to concreting or alternatively jet-washing the underside of steelwork post concrete pour. 
 +
 
 +
The use of needle head vibrating pokers is not recommended as these can encourage greater grout loss.
 +
 
 +
 
 +
Contact SMD [mailto:jharbut@smdltd.co.uk?Subject=Technical%20Info%20Query(online)-Concrete_Query&body=%20 Concrete Team] for further information.
  
  

Revision as of 14:49, 25 January 2017

Back to main Contents page


Deck sheets are designed to butt join with the ribs of the profile lined through to avoid gaps and minimise grout loss.

Metal deck is not intended to provide a watertight solution, therefore small quantities of grout and water loss are inevitable. Gaps in excess of 5mm should be sealed using either tape or expanding foam. Generally, gaps less than 5mm are acceptable with no special provision as they are too small to allow aggregate to escape, although grout loss will occur.

If the soffit and trim is intended to be fully exposed in its final condition, consideration should be give at tender stage to the taping of all joints prior to concreting or alternatively jet-washing the underside of steelwork post concrete pour.

The use of needle head vibrating pokers is not recommended as these can encourage greater grout loss.


Contact SMD Concrete Team for further information.




Other items within 11.0 - Installation - Floor deck and shear studs:-

11.0 - Installation - Floor deck and shear studs
11.1 - Cartridge tools
11.2 - Decking around columns
11.3 - Unpainted top flanges
11.4 - Mobile stud welding equipment
11.5 - Static generator or mains supply
11.6 - Testing
11.7 - Scorching of beams
11.8 - Minimising grout loss