The maximum span values in Table 8.1a are based on the following design criteria:
+
The maximum span values in [[file:8.1.jpg|Table 8.1a]] are based on the following design criteria:
: • Imposed Load of 1.5kN/m² or Line Load of 2kN/m
+
*Imposed Load of 1.5kN/m² or Line Load of 2kN/m
: • Partial Load Factor of 1.5 (considering all loads as ‘Variable’)
+
*Partial Load Factor of 1.5 (considering all loads as ‘Variable’)
: • Imposed Load Deflection Limit of Span/200
+
*Imposed Load Deflection Limit of Span/200
: • Wind Uplift of 1.5kN/m², subject to appropriate fixings
+
*Wind Uplift of 1.5kN/m², subject to appropriate fixings
: • Wind Uplift Deflection Limit of Span/90
+
*Wind Uplift Deflection Limit of Span/90
  
  
For more detailed designs, refer to '''[https://smdltd.co.uk/technical/elements-design-software/ SMD Elements ® design software version 2.0]''' for more information
+
For more detailed designs, refer to '''[https://smdltd.co.uk/technical/elements-design-software/ SMD Elements® design software version 2.0]''' for more information
  
 
'''[https://smdltd.co.uk/products-services/roof-deck/ More extensive load tables can be found on the SR product-specific data sheets]'''
 
'''[https://smdltd.co.uk/products-services/roof-deck/ More extensive load tables can be found on the SR product-specific data sheets]'''

Revision as of 16:22, 2 February 2017

Back to main Contents page


The maximum span values in Table 8.1a are based on the following design criteria:

  • Imposed Load of 1.5kN/m² or Line Load of 2kN/m
  • Partial Load Factor of 1.5 (considering all loads as ‘Variable’)
  • Imposed Load Deflection Limit of Span/200
  • Wind Uplift of 1.5kN/m², subject to appropriate fixings
  • Wind Uplift Deflection Limit of Span/90


For more detailed designs, refer to SMD Elements® design software version 2.0 for more information

More extensive load tables can be found on the SR product-specific data sheets




Other items within 8.0 - Design - Roof deck:-

8.0 - Design - Roof deck
8.1 - Quality
8.2 - Spans
8.3 - Loads
8.4 - Standard end laps
8.5 - Extended end laps
8.6 - Raking supports and cutting
8.7 - Cantilevers
8.8 - Sheet lengths
8.9 - Fire rating
8.10 - Durability
8.11 - Acoustics
8.12 - Airtightness
8.13 - Fixing specification
8.14 - Non-fragility
8.15 - Diaphragm design
8.16 - Protex® warranted insulated system
8.17 - Aesthetics